OUTPOST Wireless Callbox PC Programming
PC P
ROGRAMMABLE
O
UTPOST
C
ALLBOX
™ F
EATURES
(
CONTINUED
)
Transmit Beep Enable
This feature is turned on from the factory to provide a
short beep in the Callbox speaker any time the
ON/PTT button is pressed. This assures the Callbox
user that the radio has turned on and is ready to
transmit their message. With this feature disabled the
Callbox will only beep when the radio is first turned on.
RX Courtesy Beep Enable
In high noise environments it is sometimes difficult to
determine when a received message has ended. With
the RX Courtesy Beep enabled the Callbox will sound
a short beep on the speaker at the end of each re-
ceived transmission.
Sensor Input
The Callbox will send a warning tone when a change
in the Sensor Input is detected. The Sensor Input will
respond to an OPEN or CLOSED switch.
Narrowband
The OUTPOST™ Callbox can be programmed to op-
erate wide or narrow band on any programmable fre-
quency within the specified range.
Companding
The radio can be programmed to enable or disable
audio companding. Companding will compress trans-
mit audio before sending it, and expand receive audio
before it is heard on the speaker to reduce the back-
ground noise common in radio communications.
High / Low Power
The Callbox can be set to transmit at high (2-Watt) or
low (1-Watt) power. Low power is recommended in
battery powered installations.
Refer to
Special Note on page 3 regarding Alkaline
battery use.
S
WITCH
O
UTPUT
O
PTIONS
–A
LLOWS
C
ONTROL OF AN
E
XTERNAL
D
EVICE
..............................................................................
!
The switch output is a simple 1-Amp relay contact clo-
sure that can be used to OPEN and CLOSE a gate,
switch on a light, sound an alarm or any other applica-
tion where remote control of an ON/OFF switch is re-
quired. The OUTPOST Callbox can be PC pro-
grammed to OPEN and CLOSE the Switch Output
when one of the following programmed conditions is
met.
The Callbox can be PC programmed to alternately
OPEN and CLOSE the switch using a single 2-tone
code, or can be PC programmed for separate OPEN
and CLOSE 2-tone codes. Field programming offers
nine 2-tone codes that correspond to field program-
mable 2-tone codes available in select RITRON port-
able and base radios.
No Switch
Select this option for no switch operation.
Switch On When Called
With this option selected the switch will CLOSE when
the Callbox first receives a call. The switch will remain
CLOSED until the ON/PTT button is pressed or the
RQX Reset Time expires. This option is not applicable
if the Callbox is programmed for Automatic Turn-Off.
Switch On When Callbox in Use
This option will CLOSE the switch when the Callbox
first sends or receives a call. The switch will remain
closed until the RQX Reset Time expires, which also
turns the radio off if it is programmed for Automatic
Turn-Off.
Switch On When Active with Turn-Off Code
This option operates the same as Switch On When
Callbox in Use with the added ability to OPEN the
switch when a unique 2-Tone Turn-Off Code is re-
ceived. Unlike the Switch On When Callbox in Use
feature, the switch will not OPEN when the RQX Re-
set Time expires unless the Callbox is programmed for
Automatic Turn-Off. See the 2-Tone Decode Setting
section on page 14 of this manual for details on pro-
gramming a 2-Tone Turn-Off code.
GateGuard – Momentary for 1 sec.
With this option selected the switch will momentarily
CLOSE when a unique 2-Tone code is received. The
switch will remain CLOSED for the programmed pe-
riod of time, programmable for 1-255 seconds. See
the 2-Tone Decode Setting section of this manual for
details on programming a 2-Tone code. Field pro-
gramming the Callbox for GateGuard operation
places the radio into this momentary mode.
GateGuard – Toggle
With this option selected the switch will alternately
OPEN and CLOSE when it receives a unique 2-Tone
code. After the 2-tone code is received the Callbox will
transmit a SINGLE BEEP if the switch has been
OPENED and a DOUBLE BEEP if the switch has
been CLOSED. The switch will open when the Callbox
turns off if it is programmed for Automatic Turn-Off.
See the 2-Tone Decode Setting section of this manual
for details on programming a 2-Tone code.
GateGuard – On Code / Off Code
When this option is selected the switch will CLOSE
when a unique 2-Tone code is received, and OPEN
when the 2-Tone Turn-Off code is received. The
switch will OPEN when the Callbox turns off if it is
programmed for Automatic Turn-Off. See the 2-Tone
Decode Setting section of this manual for details on
programming a 2-Tone code and a 2-Tone Turn-Off
code.