1. INTRODUCTION
1.1 The DATAFLOW RTU from OMEGA is a complete wireless telemetry system designed to
deliver industrial instrumentation signals from a source to other instruments via radio frequency
communications. The DATAFLOW RTU allows you to access industrial measuring devices in
remote locations without running wires, installing microwave links or leasing a telephone line.
OMEGA DATAFLOW RTU and MODBUS radio communications equipment replaces these
methods.
1.2 Manual Part B is intended to provide information needed for the programming and MODBUS
control of OMEGA DATAFLOW® RTU systems. The intended readers are people familiar with
industrial instrumentation. A basic understanding of radio communi-cations is helpful. The
included information is valid only for models listed on the cover.
2.
OPERATION
2.1 DATAFLOW RTU is a radio telemetry system that operates on either UHF-FM (450-470 MHz
with transmitter power of 2 Watts or 5 Watts); or VHF-FM (150 - 165 MHz, 136 - 151 MHz,
160 - 174 MHz with transmitter power of 5 Watts). An RTU system operating in the UHF-FM
band at 2 Watts with directional antennas and 50-foot towers has an effective range of 20 to 25
miles over level terrain. Changes in the frequency of operation, transmitter power, terrain and
antenna structure will affect the range of the link.
2.2 All DATAFLOW RTU systems require FCC licensing.
3.
MICROPROCESSOR UPDATES
3.1 A microprocessor, the main controlling device of a DATAFLOW RTU, is located in a socket on
the Control Board. Socket configuration provides ease in replacing or updating microprocessor
firmware.
3.2 The microprocessor firmware version available when this manual was printed is Version 3.27.
(In Version 3.x, x represents the [number] designation of a minor revision.) OMEGA Users
Guide for DATAFLOW RTU is written for all 3.2 minor designation number DATAFLOW RTU
microprocessors.
3.3 Custom software is also available. Call OMEGA for help in determining if custom software is
cost-effective for you.
4.
PROGRAMMING KIT
4.1 A programming kit for user configuration, OMEGA part number RTU-PCPK, is available on
separate purchase. It is for connecting and providing power to the DATAFLOW RTU, and for
connecting a MODBUS PC controller to the DATAFLOW RTU.
4.2 The programming kit RTU-PCPK, consists of:
· (1) AC Power Supply, OMEGA part number RTU-PS
· (1) Computer Cable, OMEGA part number RTU-9/RTC-PAS
· (1) DATAFLOW RTU Cable, OMEGA part number RTU-PCPC
· (1) RTU Programming Software Disk, OMEGA part number RTU-PCPS-3.05
NOTE: You can download the RTU-PCPS-3.05 software from the OMEGA website at
<www.dasieee.com/>